Fire hydrants must always be operable and capable of providing adequate fire protection, so systematic maintenance and inspection are vital. It must be able to supply adequate water on demand for QFES when needed to fight a fire on your property.

Water-based fire safety installations, such as fire hydrants, are required to be tested and maintained according to the Queensland Development Code - Mandatory Part (MP) 6.1, which is a building assessment provision under the Building Act 1975, section 30. All hydrant systems also need to comply with AS1851 for maintenance inspections and the relevant design approved during construction.
Fire Hydrants should be inspected on a 6 monthly basis. However, the requirements between the 6 monthly inspection and the annual or 5 yearly inspections vary significantly considerably as detailed below:
Flow testing performed and flow values recorded. In the case of multiple fire hydrants this is carried out on the most hydraulically disadvantaged hydrant and in accordance with the original design criteria.
Referred to as a Flow and Pressure test, it is required for a baseline date prior to designing fire systems in new buildings / redeveloping existing sites.
Rebuilding or replacement of hydrant valves and optionally fire hose reel valves connected to the same system.
Fire hydrant hydrostatic test - Boosted systems - 5 Yearly basis
This is a specialised test and is only performed by our specialist wet services technicians after valve overhauls have been carried out.
Overhaul of the hydrant booster points. Involves strip down and rebuild of booster inlets using new valve washers.
Flow test performed to the most hydraulically disadvantaged hydrant, with system boosted and flow values recorded.
Safety and Fire Experts provides end-to-end Design, Certification, Installation, Commissioning and Maintenance Services for residential, commercial, and industrial clients in Brisbane and throughout Queensland.
6 monthly and annual hydrant inspection, testing and surveying 5 yearly maintenance, inspections and testing of hydrant systems Monthly and annual testing to pump sets Monthly and annual testing to water storage tanks 5 yearly maintenance of fire pump sets Hydrostatic testing of fire hydrant systems Failed flow test investigation Booster assembly testing, inspection and repairs Spring hydrant testing and repairs Defect rectification work All services for residential, commercial and industrial applications New fire hydrant system design, certification, installation and maintenance Avoid Penalties and Fine - Book Your Fire Hydrant Testing Now
Book an appointment with us to keep your site compliant with QDC MP 6.1, Australian Standards, QFES requirements and to stop any insurance claims being void due to non-compliant fire hydrants.
Safety And Fire Experts Pty Ltd ABN: 46 627 958 623 QBCC Contractors Licence No: 15156086 Electrical Contractors Licence No: 87456
1300 50 7233 Links Home News About Contact Get In Touch Facebook Linkedin